Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurosci ; 44(11)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38286627

RESUMO

Dopamine neurons play crucial roles in pleasure, reward, memory, learning, and fine motor skills and their dysfunction is associated with various neuropsychiatric diseases. Dopamine receptors are the main target of treatment for neurologic and psychiatric disorders. Antipsychotics that antagonize the dopamine D2 receptor (DRD2) are used to alleviate the symptoms of these disorders but may also sometimes cause disabling side effects such as parkinsonism (catalepsy in rodents). Here we show that GPR143, a G-protein-coupled receptor for L-3,4-dihydroxyphenylalanine (L-DOPA), expressed in striatal cholinergic interneurons enhances the DRD2-mediated side effects of haloperidol, an antipsychotic agent. Haloperidol-induced catalepsy was attenuated in male Gpr143 gene-deficient (Gpr143-/y ) mice compared with wild-type (Wt) mice. Reducing the endogenous release of L-DOPA and preventing interactions between GPR143 and DRD2 suppressed the haloperidol-induced catalepsy in Wt mice but not Gpr143-/y mice. The phenotypic defect in Gpr143-/y mice was mimicked in cholinergic interneuron-specific Gpr143-/y (Chat-cre;Gpr143flox/y ) mice. Administration of haloperidol increased the phosphorylation of ribosomal protein S6 at Ser240/244 in the dorsolateral striatum of Wt mice but not Chat-cre;Gpr143flox/y mice. In Chinese hamster ovary cells stably expressing DRD2, co-expression of GPR143 increased cell surface expression level of DRD2, and L-DOPA application further enhanced the DRD2 surface expression. Shorter pauses in cholinergic interneuron firing activity were observed after intrastriatal stimulation in striatal slice preparations from Chat-cre;Gpr143flox/y mice compared with those from Wt mice. Together, these findings provide evidence that GPR143 regulates DRD2 function in cholinergic interneurons and may be involved in parkinsonism induced by antipsychotic drugs.


Assuntos
Antipsicóticos , Transtornos Parkinsonianos , Receptores de Neurotransmissores , Humanos , Camundongos , Masculino , Animais , Cricetinae , Haloperidol/farmacologia , Levodopa/efeitos adversos , Catalepsia/induzido quimicamente , Células CHO , Cricetulus , Antipsicóticos/efeitos adversos , Interneurônios/metabolismo , Colinérgicos/farmacologia , Proteínas do Olho/metabolismo , Glicoproteínas de Membrana/metabolismo
2.
Cell Rep Med ; 4(5): 101020, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37080205

RESUMO

The excitatory glutamate α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid receptors (AMPARs) contribute to epileptogenesis. Thirty patients with epilepsy and 31 healthy controls are scanned using positron emission tomography with our recently developed radiotracer for AMPARs, [11C]K-2, which measures the density of cell-surface AMPARs. In patients with focal-onset seizures, an increase in AMPAR trafficking augments the amplitude of abnormal gamma activity detected by electroencephalography. In contrast, patients with generalized-onset seizures exhibit a decrease in AMPARs coupled with increased amplitude of abnormal gamma activity. Patients with epilepsy had reduced AMPAR levels compared with healthy controls, and AMPARs are reduced in larger areas of the cortex in patients with generalized-onset seizures compared with those with focal-onset seizures. Thus, epileptic brain function can be regulated by the enhanced trafficking of AMPAR due to Hebbian plasticity with increased simultaneous neuronal firing and compensational downregulation of cell-surface AMPARs by the synaptic scaling.


Assuntos
Epilepsia , Receptores de AMPA , Humanos , Receptores de AMPA/fisiologia , Neurônios , Convulsões
3.
J Neurochem ; 165(2): 177-195, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36807226

RESUMO

Dopamine (DA) is involved in neurological and physiological functions such as motor control. L-3,4-dihydroxyphenylalanine (L-DOPA), a precursor of DA, is conventionally believed to be an inert amino acid precursor of DA, and its major therapeutic effects in Parkinson's disease (PD) are mediated through its conversion to DA. On the contrary, accumulating evidence suggests that L-DOPA itself is a neurotransmitter. We here show that L-DOPA potentiates DA D2 receptor (DRD2) signaling through GPR143, the gene product of X-linked ocular albinism 1, a G-protein-coupled receptor for L-DOPA. In Gpr143-gene-deficient (Gpr143-/y ) mice, quinpirole, a DRD2/DRD3 agonist, -induced hypolocomotion was attenuated compared to wild-type (WT) mice. Administration of non-effective dose of L-DOPA methyl ester augmented the quinpirole-induced hypolocomotion in WT mice but not in Gpr143-/y mice. In cells co-expressing GPR143 and DRD2, L-DOPA enhanced the interaction between GPR143 and DRD2 and augmented quinpirole-induced decrease in cAMP levels. This augmentation by L-DOPA was not observed in cells co-expressing GPR143 and DRD1 or DRD3. Chimeric analysis in which the domain of GPR143 was replaced with GPR37 revealed that GPR143 interacted with DRD2 at the fifth transmembrane domain. Intracerebroventricular administration of a peptide that disrupted the interaction mitigated quinpirole-induced behavioral changes in WT mice but not in Gpr143-/y mice. These findings provide evidence that coupling between GPR143 and DRD2 is required for selective DRD2 modulation by L-DOPA in the dorsal striatum.


Assuntos
Levodopa , Doença de Parkinson , Receptores de Dopamina D2 , Animais , Camundongos , Corpo Estriado/metabolismo , Dopamina/metabolismo , Levodopa/farmacologia , Doença de Parkinson/metabolismo , Quimpirol/farmacologia , Quimpirol/metabolismo , Receptores de Dopamina D1/metabolismo , Receptores de Dopamina D2/metabolismo , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo
4.
Nucl Med Biol ; 110-111: 47-58, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35642985

RESUMO

INTRODUCTION: AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor) receptors play a central role in neurotransmission and neuronal function. A positron emission tomography (PET) tracer for AMPA receptors, [11C]K-2, was recently developed by us to visualize AMPA receptors in the living human brain. [11C]K-2 is a derivative of 4-[2-(phenylsulphonylamino)ethylthio]-2,6-difuluoro-phenoxyacetamide (PEPA), and is labeled with the radioactive isotope 11C, which has a short half-life. PET drugs are usually labeled with 18F because of its long half-life. Therefore, we screened and identified potential 18F-labeled PET drugs for AMPA receptors (AMPA-PET drugs), which could provide an image equivalent to that of [11C]K-2. METHODS: Derivatives of K-2 labeled with 18F were synthesized and administered to rats and PET imaging was performed. The transferability of each compound to the brain and its correlation with the PET image of [11C]K-2 were evaluated from the obtained PET images. Furthermore, the specific binding ability of promising compounds to the AMPA receptor was evaluated by the PET imaging of rats, which we specifically knocked down the expression of AMPA by the lentivirus-mediated introduction of short hairpin RNA (shRNA) targeted to subunits of the AMPA receptor (GluA1-A3). The specific binding ability was also evaluated through electrophysiological experiments with acute brain slices. RESULTS: Some of the synthesized 18F-labeled candidate compounds showed a distribution similar to that of K-2, with reasonable transferability to the brain. In addition, from the evaluation of the specific binding ability to the AMPA receptor, a promising structure of an 18F-labeled AMPA PET drug was identified. This study also revealed that the alkylation of the sulfonamide group of PEPA enhances brain transferability.


Assuntos
Flúor , Receptores de AMPA , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Flúor/metabolismo , Radioisótopos de Flúor/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Ratos , Receptores de AMPA/metabolismo , Ácido alfa-Amino-3-hidroxi-5-metil-4-isoxazol Propiônico/metabolismo
5.
Neurosci Res ; 173: 106-113, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34033829

RESUMO

The glutamate α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid receptors (AMPARs) is an important molecule in neurotransmission. We have recently developed the first positron emission tomography (PET) tracer [11C]K-2 to visualize and quantify AMPARs in the living human brain. After injection, [11C]K-2 is hydrolyzed at the terminal amide (and is thus metabolized to a major metabolite, [11C]K-2OH) within 10 min, representing the PET image in rodents and humans. Here, we found that K-2OH did not penetrate the cell membrane but slowly passed through the blood brain barrier (BBB) with paracellular transport. Furthermore, major efflux transporters in the BBB did not carry K-2OH. Logan graphical analysis exhibited reversible binding kinetics of this radiotracer in healthy individuals; these results demonstrated that the PET image of this tracer represents cell surface AMPARs with passive penetration of [11C]K-2OH through the BBB, resulting in reversible binding kinetics. Thus, PET images with this tracer depict the physiologically crucial fraction of AMPARs.


Assuntos
Tomografia por Emissão de Pósitrons , Receptores de AMPA , Barreira Hematoencefálica/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Receptores de AMPA/metabolismo , Ácido alfa-Amino-3-hidroxi-5-metil-4-isoxazol Propiônico
6.
Sci Rep ; 11(1): 1598, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-33452361

RESUMO

[11C]K-2, a radiotracer exhibiting high affinity and selectivity for α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid receptors (AMPARs), is suitable for the quantification of AMPARs in living human brains and potentially useful in the identification of epileptogenic foci in patients. This study aimed to estimate the radiation doses of [11C]K-2 in various organs and calculate the effective dose after injection of [11C]K-2 in healthy human subjects. Twelve healthy male subjects were registered and divided into two groups (370 or 555 MBq of [11C]K-2), followed by 2 h whole-body scans. We estimated the radiation dose of each organ and then calculated the effective dose for each subject. The highest uptake of [11C]K-2 was observed in the liver, while the brain also showed relatively high uptake. The urinary bladder exhibited the highest radiation dose. The kidneys and liver also showed high radiation doses after [11C]K-2 injections. The effective dose of [11C]K-2 ranged from 5.0 to 5.2 µSv/MBq. Our findings suggest that [11C]K-2 is safe in terms of the radiation dose and adverse effects. The injection of 370-555 MBq (10 to 15 mCi) for PET studies using this radiotracer is applicable in healthy human subjects and enables serial PET scans in a single subject.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/química , Receptores de AMPA/metabolismo , Adulto , Radioisótopos de Carbono/química , Voluntários Saudáveis , Humanos , Rim/química , Rim/metabolismo , Fígado/química , Fígado/metabolismo , Masculino , Radiometria , Compostos Radiofarmacêuticos/farmacocinética , Receptores de AMPA/química , Distribuição Tecidual , Bexiga Urinária/química , Bexiga Urinária/metabolismo , Adulto Jovem
7.
Nat Med ; 26(2): 281-288, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31959988

RESUMO

Although aberrations in the number and function of glutamate AMPA (α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid) receptors are thought to underlie neuropsychiatric disorders, no methods are currently available for visualizing AMPA receptors in the living human brain. Here we developed a positron emission tomography (PET) tracer for AMPA receptors. A derivative of 4-[2-(phenylsulfonylamino)ethylthio]-2,6-difluoro-phenoxyacetamide radiolabeled with 11C ([11C]K-2) showed specific binding to AMPA receptors. Our clinical trial with healthy human participants confirmed reversible binding of [11C]K-2 in the brain according to Logan graphical analysis (UMIN000020975; study design: non-randomized, single arm; primary outcome: dynamics and distribution volumes of [11C]K-2 in the brain; secondary outcome: adverse events of [11C]K-2 during the 4-10 d following dosing; this trial met prespecified endpoints). In an exploratory clinical study including patients with epilepsy, we detected increased [11C]K-2 uptake in the epileptogenic focus of patients with mesial temporal lobe epilepsy, which was closely correlated with the local AMPA receptor protein distribution in surgical specimens from the same individuals (UMIN000025090; study design: non-randomized, single arm; primary outcome: correlation between [11C]K-2 uptake measured with PET before surgery and AMPA receptor protein density examined by biochemical study after surgery; secondary outcome: adverse events during the 7 d following PET scan; this trial met prespecified endpoints). Thus, [11C]K-2 is a potent PET tracer for AMPA receptors, potentially providing a tool to examine the involvement of AMPA receptors in neuropsychiatric disorders.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Radioisótopos de Carbono/química , Fenoxiacetatos/farmacocinética , Receptores de AMPA/metabolismo , Adulto , Animais , Cromatografia Líquida , Feminino , Voluntários Saudáveis , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Ligação Proteica , Ratos , Ratos Sprague-Dawley , Espectrometria de Massas em Tandem , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento , Adulto Jovem
8.
PLoS One ; 13(2): e0192549, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29432459

RESUMO

Standardized uptake values (SUVs) are the most widely used quantitative imaging biomarkers in PET. It is important to evaluate the variability and repeatability of measured SUVs. Phantom studies seem to be essential for this purpose; however, repetitive phantom scanning is not recommended due to the decay of radioactivity. In this study, we performed count-based image reconstruction to avoid the influence of decay using two different PET/CT scanners. By adjusting the ratio of 18F-fluorodeoxyglucose solution to tap water, a NEMA IEC body phantom was set for SUVs of 4.0 inside six hot spheres. The PET data were obtained using two scanners (Aquiduo and Celesteion; Toshiba Medical Systems, Tochigi, Japan). We set the start time for image reconstruction when the total radioactivity in the phantom was 2.53 kBq/cc, and employed the counts of the first 2-min acquisition as the standard. To maintain the number of counts for each image, we set the acquisition time for image reconstruction depending on the decay of radioactivity. We obtained 50 images, and calculated the SUVmax and SUVpeak of all six spheres in each image. The average values of the SUVmax were used to calculate the recovery coefficients to compare those measured by the two different scanners. Bland-Altman analyses of the SUVs measured by the two scanners were also performed. The measured SUVs using the two scanners exhibited a 10-30% difference, and the standard deviation (SD) of the measured SUVs was between 0.1-0.2. The Celesteion always exhibited higher values than the Aquiduo. The smaller sphere exhibited a larger SD, and the SUVpeak had a smaller SD than the SUVmax. The Bland-Altman analyses showed poor agreement between the SUVs measured by the two scanners. The recovery coefficient curves obtained from the two scanners were considerably different. The Celesteion exhibited higher recovery coefficients than the Aquiduo, especially at approximately 20-mm-diameter. Additionally, the curves were lower than those calculated from the standard 30-min acquisition images. We propound count-based image reconstruction to evaluate the variability and repeatability of measured SUVs. These results are also applicable for the standardization and harmonization of SUVs in multi-institutional studies.


Assuntos
Imagens de Fantasmas , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
9.
Am J Nucl Med Mol Imaging ; 7(5): 204-211, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29181267

RESUMO

Standardized uptake values (SUVs) are the most widely used quantitative imaging biomarkers in positron emission tomography (PET); however, little is known about the changes in variation and repeatability of SUVs depending on the magnitude of the values. We hypothesized that low SUVs have larger variations than high SUVs, and attempted various kinds of experimental PET scans using a phantom. By adjusting the ratio of F-18 solution to tap water, a NEMA IEC body phantom was set for SUVs of 2.0, 4.0, and 8.0 inside six hot spheres. PET data were obtained for 4 hours, and the data reconstructed every 2 min. The SUVmax and SUVpeak of the spheres in all images were recorded. The relative SUVs were calculated by dividing the measured SUV by actual SUV, and used for the Bland-Altman plots. Some variation was observed for the measured SUVs. The measured SUVs for the actual SUV of 2.0 showed the largest variation among those of 2.0, 4.0, and 8.0, and those of 8.0 showed the smallest. Similarly, the relative SUVs showed significantly larger variations for lower values. In addition, the relative SUVmax showed larger variation and value than the relative SUVpeak. The Bland-Altman plots showed considerable variation and little agreement, but the degree of variation decreased as the measured value increased. We demonstrated some variation of the measured SUVs, which decreased for larger measured values. Clinicians should consider the inaccuracy of low SUVs not only in daily practice, but also for multi-institutional studies.

10.
EJNMMI Res ; 7(1): 83, 2017 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-29022216

RESUMO

BACKGROUND: The goal of this study was to evaluate the performance of the Celesteion positron emission tomography/computed tomography (PET/CT) scanner, which is characterized by a large-bore and time-of-flight (TOF) function, in accordance with the NEMA NU-2 2012 standard and version 2.0 of the Japanese guideline for oncology fluorodeoxyglucose PET/CT data acquisition protocol. Spatial resolution, sensitivity, count rate characteristic, scatter fraction, energy resolution, TOF timing resolution, and image quality were evaluated according to the NEMA NU-2 2012 standard. Phantom experiments were performed using 18F-solution and an IEC body phantom of the type described in the NEMA NU-2 2012 standard. The minimum scanning time required for the detection of a 10-mm hot sphere with a 4:1 target-to-background ratio, the phantom noise equivalent count (NECphantom), % background variability (N 10mm), % contrast (Q H,10mm), and recovery coefficient (RC) were calculated according to the Japanese guideline. RESULTS: The measured spatial resolution ranged from 4.5- to 5-mm full width at half maximum (FWHM). The sensitivity and scatter fraction were 3.8 cps/kBq and 37.3%, respectively. The peak noise-equivalent count rate was 70 kcps in the presence of 29.6 kBq mL-1 in the phantom. The system energy resolution was 12.4% and the TOF timing resolution was 411 ps at FWHM. Minimum scanning times of 2, 7, 6, and 2 min per bed position, respectively, are recommended for visual score, noise-equivalent count (NEC)phantom, N 10mm, and the Q H,10mm to N 10mm ratio (QNR) by the Japanese guideline. The RC of a 10-mm-diameter sphere was 0.49, which exceeded the minimum recommended value. CONCLUSIONS: The Celesteion large-bore PET/CT system had low sensitivity and NEC, but good spatial and time resolution when compared to other PET/CT scanners. The QNR met the recommended values of the Japanese guideline even at 2 min. The Celesteion is therefore thought to provide acceptable image quality with 2 min/bed position acquisition, which is the most common scan protocol in Japan.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...